1.2.5. Filter Test (FT)
This filter test should filter all packets with the same source MAC address and destination MAC Address.
For this test, test packets sent are all with the same source MAC address and destination MAC address
and the DUT should filter this kind of packet.
Perform filter test on DUT in layer2 with different speeds, mode and various configurations. The
following tasks transmit frames with same DA (destination address) and SA (source address).
PT2-FT-10H
PT2-FT-10F
PT2-FT-100H
PT2-FT-100F
PT2-FT-1G
PT2-FT-10G
1.2.6. CRC Error Test (CRC)
Perform CRC (Cyclic Redundancy Check) error test on DUT in layer2 with different speeds, mode and
various configurations for the last 4 bytes of CRC to be filtered. For normal DUT, frame with error CRC
should be filtered. The following tasks transmit frames with CRC errors
.
PT2-CRC-10H, (10Mbps, Half Duplex)
PT2-CRC-10F, (10Mbps, Full Duplex)
PT2-CRC-100H, (100Mbps, Half Duplex)
PT2-CRC-100F, (100Mbps, Full Duplex)
PT2-CRC-1G, (1Gbps, Full Duplex)
PT2-CRC-10G, (10Gbps, Full Duplex)