5.5. Test Task AC
Test Task AC allows you to test DUT‟s power supply. For more detail description regarding to Test
Task AC, please refer to “1.3.5. AC Test”. Please note that if you don‟t have XM-2WL1 module card
installed on your chassis, you can‟t run tasks mentioned here.
5.5.1. PWR-Setup (Power Setup Test)
With module card XM-2WL1 providing power to the DUT, you can perform power ON/OFF and cycling
tests with PWR-Setup.
Setup
Power Control: To turn the power of DUT ON or OFF.
Zero/Peak Cross: In a Voltage vs. Time diagram shown on the
right, a Zero Cross happens every time when the value of
voltage reaches zero. Zero-crossing is the key to determining
the proper switching time (phase angle) in both leading edge
and trailing edge dimmers. You can set the crossing mode to 0
to 270 degrees here, or you can set the crossing mode to
Free-run mode.
Cycle Setting: By click the Enable Cycle Reboot check-box, you can perform power on/off
cycling tests.
Initial/End: You can set the starting/ending power status to ON/OFF here in these fields.
Count: You can set how many times you would like to run the power on/off cycling test.
Interval: You can set the amount of seconds system shall wait between each cycling test.
Wait before Power ON/OFF: System will halt for the set amount of seconds before power on/off.
Wait after Power ON/OFF: System will halt for the set amount of seconds after power on/off.