NuStreams-P9M User Manual USM Ver 2.1
102. Hardware Installation for Testing DUTs As we mentioned in “1.3 Residential Gateway & Switch”, NuStreams-P9M can perform tests on Residentia
11 2.2. For Switch Test While performing tests on Switch, DUT LAN ports must be connected to NuStreams-P9M with CAT-5 UTP cables as shown in the
123. NuStreams-P9M Control Buttons & LCD All parameters for DUT tests can be configured via NuStreams-P9M’s control buttons located on its front
133.2. NuStreams-P9M LCD Overview All configuration options and system information can be viewed via NuStreams-P9M’s LCD screen. All options and the
143.3. Operating NuStreams-P9M with Control Buttons & LCD This section contains detailed instructions about setting your NuStreams-P9M via contr
15Test Configuring & Performing Function Control Button Action LCD Display Entering Test Setting Menu Move the > cursor to “Test Setting”, a
16Test Log Management Function Control Button Action LCD Display Entering Test Log Menu Move the > cursor to “Test Log”, and press button. Vi
17System Configuration/Information Function Control Button Action LCD Display Entering System Setting Menu Move the > cursor to “System Settin
184. NuStreams-P9M Utility NuStreams-P9M comes with GUI (Graphic User Interface) configuration utility software that runs under Microsoft Windows
19 4.1. Installing NuStreams-P9M Utility Software Please follow the steps down below to install NuStreams-P9M Utility Software: 1. Double click N
2Foreword Copyright Copyright © 2010 Xtramus Technologies, all rights reserved. The information contained in this document is the property of Xtramu
203. Input the User Name and the Organization (optional), and click “Next” 4. Choose which folder you would like to install NuStreams-P9M utility s
21 6. NuStreams-P9M utility software installation complete. Click “Finish” to close the InstallShield Wizard. XTRAMUS TECHNOLOGIES®E-mail: sale
224.2. Uninstalling NuStreams-P9M Utility Software To uninstall NuStreams-P9M Utility Software, please click Start → Programs → NuStreams → APMPT-
234.3. NuStreams-P9M Utility Demo Mode After installing NuStreams-P9M utility software properly, an icon will appear on your desktop. You can dou
244.4. Connecting NuStreams-P9M to PC As mentioned in the sections above, for NuStreams-P9M utility software to work properly, your PC must be conne
254.5. NuStreams-P9M Utility Functions 4.5.1. NuStreams-P9M Utility Main Window Overview Function Descriptions Menu Bar The Menu Bar allows you t
264.5.2. Menu Bar NuStreams-P9M Menu Bar includes configuration options such as File, Task, Log, Service, Language, and Help. File Load Default Co
27Task Get Task This function allows NuStreams-P9M utility software to access all test settings (Run) from NuStreams-P9M and show those settings in
28Service If NuStreams- P9M’s password has been changed, you could reset it to default (▲/+ ▲/+ ▲/+ ▲/+) by “Clear Device Password” function. A “C
294.5.3. Quick Launch Buttons These Quick Launch Buttons allow you to reconnect NuStreams-P9M, access test setting files from your PC or NuStreams-
3Revision History Date USM Version History November. 10, 2008 1.0 July,2009 1.1 Modify NuStreams-P9M Utility July,2009 1.2 Modify NuStreams-P9
30Get Task/Apply All By clicking Get Task button, you can load test settings from NuStreams-P9M, display all settings in Info/Run Select List and Ma
314.5.4. Info/Run Select List The Info/Run Select List contains a list of selectable options. When selected, the Main Display Window will show th
32Test List To access test settings stored in NuStreams-P9M, please click button located on the Quick Launch Buttons section so the utility softw
334.5.5. Main Display Window The Main Display Window displays NuStreams-P9M’s detailed System Information and Test List which contains all test p
34Modifying Run Title You can modify titles for all Runs listed on Info/Run Select List. • A: Run Title. You can modify title names here. • B:
35DUT: Router Test Type/DUT Description • DUT: Choose “Router” from this scroll-down menu to start configuring router tests. • Get DUT Descript
36DUT: Switch Test Type/DUT Description • DUT: Choose “Switch” from this scroll-down menu to start configuring switch tests. Media Type • Testing
37DUT: Router + Switch Test Type • DUT: Choose “Router + Switch” from this scroll-down menu to start configuring tests for both routers and switche
38Test Traffic • Protocol Type: You can set the protocol used (HTTP, UDP, or FTP) for DUT tests. • Test Utilization (%): Utilization is the traff
394.6. Firmware/FPGA/NuPAD Upgrade As mentioned above in “4.5.2. Menu Bar”, by clicking Service → System Upgrade on the Menu Bar, you can upgrade
4Table of Contents Foreword ...
40Firmware/FPGA Upgrading To start upgrading NuStreams-P9M firmware /FPGA , click Service → System Upgrade on the Menu Bar, and choose if you wou
41NuStreams-P9M’s LCD will show the firmware/FPGA upgrading process as shown in the figures down below. NuStreams-P9M Firmware Upgrading FPGA Upgr
42NuPAD Firmware Upgrading Before upgrading NuPAD’s firmware, please connect NuPAD, NuStreams-P9M, and your PC according to the figures and descript
43NuPAD’s LCD screen will show the firmware upgrading process as shown in the pictures down below: Firmware upgrading completes. Please click
445. NuPAD NuPAD is an assistant extension keypad, especially designed for running tests at mass production line. With all test parameters set and
455.2. Connecting NuPAD with NuSTreams-P9M Before using NuPAD as NuStreams-P9M’s assistant extension keypad, you have to connect NuPAD’s Connection
465.3. Starting DUT Tests with NuPAD NuPAD has 3 buttons on its front panel: “|| Pause”, “ Stop”, and “► Run”. After connecting NuPAD with NuStrea
51. NuStreams-P9M Overview 1.1. General Description of NuStreams-P9M NuStreams-P9M is a stand-alone tester for testing switches and routers (with
61.2. Residential Gateway & Switch NuStreams-P9M can perform tests on Residential Gateway (Broadband Router) and Switch. Tests for Residential G
71.3. NuStreams-P9M Panel Functions Overview NuStreams-P9M’s LEDs, buttons, and interface ports are located on its Front, Left and Right Side Panels
8Left Panel Port Function Console Connecting NuStreams-P9M with Xtramus NuPAD for test management Mini-USB Connecting NuStreams-P9M with PC fo
91.4. NuStreams-P9M LED Status The table down below contains NuStreams-P9M’s front panel LED status and their meanings. LED Status Description